← All appsStructCalc.Online / Help

Application guide

PlatformCalc

Working platforms.

What this tool does

PlatformCalc checks working-platform loading using a simple load-spread route or its simplified BR 470-style punching route. The guide explains the inputs and geotechnical checks outside the app’s scope.

Application version: v4.

Open PlatformCalcContact support

Check a working platform

  1. Select the calculation route: the simple spread check or the BR 470-style punching check.
  2. Enter the plant or wheel loading, contact dimensions and platform thickness. Confirm load factors and the load-spread geometry.
  3. Describe the platform material and subgrade. In BR 470 mode use characteristic undrained strength for cohesive soil, or friction angle and unit weight for granular soil.
  4. Enter any geogrid information and check its product properties and placement against the design basis.
  5. Run the calculation and review the pressure, punching and stated assumptions. Compare the result with the project ground information and construction requirements.

Calculation routes and limits

Independent design checks

This is a preliminary calculation aid. It does not replace full geotechnical design, settlement assessment, cyclic degradation review, edge stability, ground verification, construction quality control or a product-specific geosynthetic design. Confirm the applicable BR 470 clauses and project factors before use.

Tips and field guidance

Theoretical basis

This revision keeps the original simple working-platform load-spread check and adds a simplified BR 470-style punching check. The BR 470 mode is intended for independent preliminary checks and transparent reporting of assumptions.

Theoretical basis

The app does not replace a full geotechnical design, project-specific ground model, settlement assessment, cyclic degradation review, edge stability check, construction quality control assessment or product-specific geosynthetic design.

Ground Data

BR 470 mode uses cu,k for cohesive subgrade, or φ′k and γ for granular subgrade. Allowable bearing pressure is retained for the simple spread fallback.

Ground Data

Simple spread mode checks the dispersed pressure against the entered allowable bearing pressure. CBR, cu, φ′ and γ are recorded for context.

Platform Data

Defaults are φ′platform = 40° and γplatform = 20 kN/m³. Geogrid strength is reported, but no numerical thickness reduction is taken without a product-specific design.

Platform Data

Simple spread mode uses thickness, spread ratio and allowable bearing pressure. Platform γ and φ′ are saved but not required for the simple check.

Load Cases

Use Ctrl+I to insert a row and Ctrl+Y to delete the active row. Selecting Track, Wheel, Strip or Rectangular pad will prefill blank contact dimensions.

Load Cases

BR 470 Case 1 and Case 2 are generated automatically from each included load row and shown in the Results tab/report.

Verification Examples

These fixed examples regression-test the calculation engine. They are not project design examples; they are guard rails so later revisions do not silently change core values.

What is checked

The tests check cohesive BR 470-style punching, granular Nγ interpolation, a deliberate failure case, and the legacy simple spread calculation. Expected values are hard-coded to 3 decimal places.

Report Notes

The report preview is on the right-hand pane. It includes the selected method note, intermediate BR 470 terms and validation warnings.

Method

Choose either the legacy load-spread bearing check or the simplified BR 470 punching check.

Subgrade type

Select the subgrade model used by the BR 470 punching check.

CBR %

Recorded for correlation / context. Not directly used unless you choose to interpret it outside the app.

cu,k kPa

Characteristic undrained shear strength for cohesive subgrade.

Subgrade φ′k degrees

Characteristic effective friction angle for granular subgrade.

Subgrade γ kN/m³

Subgrade bulk unit weight used in the granular bearing term.

Allowable bearing kPa

Fallback bearing pressure used by the simple spread method.

Platform φ′k degrees

Characteristic friction angle of platform material used in Kp tanδ.

Platform γ kN/m³

Platform bulk unit weight used in BR 470 punching and retained for legacy data compatibility.

Minimum thickness m

Lower-bound platform thickness; BR 470 mode also checks geogrid cover if selected.

Geogrid included

Geogrid is reported and cover is enforced; strength is not used for a product-specific reduction in this simplified mode.

Td,k kN/m

Characteristic tensile strength of geosynthetic reinforcement.

Geogrid cover m

Minimum cover above geogrid. The app enforces at least 0.30 m in BR 470 mode.

Frequently asked questions

Which checks are available in PlatformCalc?

PlatformCalc provides a simple load-spread bearing check and a simplified BR 470-style punching check using the selected subgrade inputs.

Does PlatformCalc cover every working-platform risk?

No. The documented routes do not replace a project ground model, settlement assessment, edge stability, construction quality control or product-specific geosynthetic design.